Sauer Compressors USA - Item # WP 22L Air Cooled Compressor
      
 
Home About Us Products News Contact Us
  
 
Sauer Compressors
Customize your Sauer Compressor here!!!
Sauer Compressors
Search Catalog 
      GO   
 All Categories    2 Stage Air Cooled Compressors up to 600 PSI
Visit Us at the HydroVision International!
All Categories > 4 Stage Air Cooled Compressors up to 6000 PSI > 4 Stage Water Cooled Compressors up to 5075 PSI > 2 Stage Air Cooled Compressors up to 600 PSI > Item # WP 22L Air Cooled Compressor  
    Download PDF Download PDF     Print Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # WP 22L Air Cooled Compressor



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

2-stage-air-cooled

larger image
The 2-stage air-cooled compressors helped establish Sauer’s reputation for high quality. After 75 years of production, thesemodels are now in their third generation of development. These models are designed to have the following advantages:

Direct drive (no belt maintenance)
Light weight with small installation footprint
Engineered for continuous operation in extreme environments
Extended operation time betweenrequired maintenance intervals (2000 operating hours)




Specifications · Flow and Power

Specifications

Stages/Cylinders

2/2

Operating Pressure Range

100 to 580 psi

Required Power @ 1150 RPM, 60 Hz

4 to 4.7 hp

Capacity F. A. D. @ 1150 RPM, 60 Hz

8.24 to 9.18 SCFM

Required Power @ 1770 RPM, 60 Hz

6.3 to 7.6 hp

Capacity F. A. D. @ 1770 RPM, 60 Hz

12 to 14 SCFM

Motor Rating @ 1170 RPM, 60 Hz

5 (3.6KW) hp

Motor Rating @ 1770 RPM, 60 Hz

8.6 (6.4KW) hp

Current @ 460 Volts @ 1170 RPM, 60 Hz

8.1 Amps

Current @ 460 Volts @ 1770 RPM, 60 Hz

11.5 Amps

Current @ 230 Volts @ 1170 RPM, 60 Hz

16.2 Amps

Current @ 230 Volts @ 1770 RPM, 60 Hz

23 Amps

Weight @ 1170 RPM, 60 Hz

297 Pound

Weight @ 1770 RPM, 60 Hz

297 Pound

Noise level @ 3 ft, 1170 RPM (60Hz)

83 dB(A)

Noise level @ 3 ft, 1770 RPM (60Hz)

87 dB(A)

Heat Dissipation @ 1170 RPM, 60 Hz

17,000 Btu/hr

Heat Dissipation @ 1770 RPM, 60 Hz

27,000 Btu/hr

Cooling Air Needed @ 1170 RPM, 60 Hz

410 CFM

Cooling Air Needed @ 1770 RPM, 60 Hz

760 CFM

Residual oil content at gas outlet (without filtration)

<5 mg/m³

Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz

18 ºF

Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz

25 ºF

Operational ambient temperature range

40-140 ºF

Oil Sump Capacity

1.6 Quarts

Overall Dimensions ( L x W x H )

34 X 24 X 25 Inch

Cooling Method

Air Cooled

Drive Type

Direct Drive

Inlet Pressure

1 psi


Flow and Power

Power @ 145 PSIG, 1170 RPM, 60 Hz

4.0 hp

Flow @ 145 PSIG, 1170 RPM, 60 Hz

9.2 SCFM

Power @ 145 PSIG, 1770 RPM, 60 Hz

6.3 hp

Flow @ 145 PSIG, 1770 RPM, 60 Hz

14.2 SCFM

Power @ 290 PSIG, 1170 RPM, 60 Hz

4.2 hp

Flow @ 290 PSIG, 1170 RPM, 60 Hz

8.8 SCFM

Power @ 290 PSIG, 1770 RPM, 60 Hz

6.4 hp

Flow @ 290 PSIG, 1770 RPM, 60 Hz

13.6 SCFM

Power @ 435 PSIG, 1170 RPM, 60 Hz

4.7 hp

Flow @ 435 PSIG, 1170 RPM, 60 Hz

8.6 SCFM

Power @ 435 PSIG, 1770 RPM, 60 Hz

7.2 hp

Flow @ 435 PSIG, 1770 RPM, 60 Hz

13.3 SCFM

Power @ 580 PSIG, 1170 RPM, 60 Hz

5.0 hp

Flow @ 580 PSIG, 1170 RPM, 60 Hz

8.2 SCFM

Power @ 580 PSIG,1770 RPM, 60 Hz

7.6 hp

Flow @ 580 PSIG, 1770 RPM, 60 Hz

12.4 SCFM