Sauer Compressors USA - Item # WP 100 Water Cooled Compressor
Home
2 Stage Air Cooled Compressors
up to 600 PSI
3 Stage Air Cooled Compressors
up to 1015 PSI
4 Stage Air Cooled Compressors
up to 6000 PSIs
2 Stage Water Cooled Compressors
up to 450 PSI
4 Stage Water Cooled Compressors
up to 5075 PSI
Boosters and Gas Compressors
Customized Solutions
Conversion Calculator
Sitemap
Request for Quote
Search Catalog
By Keyword
By Item #
All Categories
2 Stage Water Cooled Compressors up to 450 PSI
All Categories
>
2 Stage Water Cooled Compressors up to 450 PSI
>
Item # WP 100 Water Cooled Compressor
Download PDF
Printable Page
Email This Page
Save To Favorites
Item # WP 100 Water Cooled Compressor
Download PDF
Email This Page
Save To Favorites
larger image
The Alternative to Air-Cooled Compressors
With over 75 years of commercial and naval experience, Sauer Compressors hasdeveloped a series of highly competitive, robust, water-cooled compressors. Theseunits are ideal for industrial applications where airflow, high ambient temperatures,and/or ambient noise pose operational difficulties.
Specifications
·
Flow and Power
Specifications
Stages/Cylinders
2/2
Operating Pressure Range
100 to 435 psi
Required Power @ 1150 RPM, 60 Hz
19.1 to 21.3 hp
Capacity F. A. D. @ 1150 RPM, 60 Hz
41 to 44 SCFM
Required Power @ 1770 RPM, 60 Hz
28.5 to 31.7 hp
Capacity F. A. D. @ 1770 RPM, 60 Hz
60.8 to 65.1 SCFM
Motor Rating @ 1170 RPM, 60 Hz
20 hp
Motor Rating @ 1770 RPM, 60 Hz
30 hp
Current @ 460 Volts @ 1170 RPM, 60 Hz
23.5 Amps
Current @ 460 Volts @ 1770 RPM, 60 Hz
34.4 Amps
Current @ 230 Volts @ 1770 RPM, 60 Hz
74 Amps
Current @ 230 Volts @ 1170 RPM, 60 Hz
68.8 Amps
Weight @ 1170 RPM, 60 Hz
1100 Pound
Weight @ 1770 RPM, 60 Hz
1100 Pound
Noise level @ 3 ft, 1170 RPM (60Hz)
82 dB(A)
Noise level @ 3 ft, 1770 RPM (60Hz)
86 dB(A)
Heat dissipation to water @ 1170 RRM, 60Hz
55,000 Btu/hr
Heat dissipation to water @ 1770 RRM, 60Hz
55,000 Btu/hr
Heat dissipation to ambient @ 1170 RRM, 60Hz
10,000 Btu/hr
Heat dissipation to ambient @ 1770 RRM, 60Hz
17,000 Btu/hr
Cooling Air Needed @ 1170 RPM, 60 Hz
6.1 GPM
Cooling Air Needed @ 1770 RPM, 60 Hz
9.2 GPM
Residual oil content at gas outlet (without filtration)
<5 mg/m³
Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz
27 ºF
Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz
31 ºF
Operational ambient temperature range
40-120 ºF
Oil Sump Capacity
9.5 Quarts
Overall Dimensions ( L x W x H )
53 X 28 X 33 Inch
Cooling Method
Water-Cooled
Drive Type
Direct Drive
Flow and Power
Power @ 145 PSIG, 1170 RPM, 60 Hz
19.1 hp
Flow @ 145 PSIG, 1170 RPM, 60 Hz
44.0 SCFM
Power @ 145 PSIG, 1770 RPM, 60 Hz
28.5 hp
Flow @ 145 PSIG, 1770 RPM, 60 Hz
65.1 SCFM
Power @ 290 PSIG, 1170 RPM, 60 Hz
20.2 hp
Flow @ 290 PSIG, 1170 RPM, 60 Hz
42.6 SCFM
Power @ 290 PSIG, 1770 RPM, 60 Hz
30.1 hp
Flow @ 290 PSIG, 1770 RPM, 60 Hz
62.9 SCFM
Power @ 435 PSIG, 1170 RPM, 60 Hz
21.3 hp
Flow @ 435 PSIG, 1170 RPM, 60 Hz
41.2 SCFM
Power @ 435 PSIG, 1770 RPM, 60 Hz
31.7 hp
Flow @ 435 PSIG, 1770 RPM, 60 Hz
60.8 SCFM
DOWNLOADS
2 Stage Water Cooled Performance Charts
(PDF, 81KB)
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666