Sauer Compressors USA - Item # WP 100 Water Cooled Compressor
      
 
Home About Us Products News Contact Us
  
 
Sauer Compressors
Customize your Sauer Compressor here!!!
Sauer Compressors
Search Catalog 
      GO   
 All Categories    2 Stage Water Cooled Compressors up to 450 PSI
Visit Us at the HydroVision International!
All Categories > 2 Stage Water Cooled Compressors up to 450 PSI > Item # WP 100 Water Cooled Compressor  
    Download PDF Download PDF     Print Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # WP 100 Water Cooled Compressor



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

2-Stage-water-cooled

larger image
The Alternative to Air-Cooled Compressors
With over 75 years of commercial and naval experience, Sauer Compressors hasdeveloped a series of highly competitive, robust, water-cooled compressors. Theseunits are ideal for industrial applications where airflow, high ambient temperatures,and/or ambient noise pose operational difficulties.




Specifications · Flow and Power

Specifications

Stages/Cylinders

2/2

Operating Pressure Range

100 to 435 psi

Required Power @ 1150 RPM, 60 Hz

19.1 to 21.3 hp

Capacity F. A. D. @ 1150 RPM, 60 Hz

41 to 44 SCFM

Required Power @ 1770 RPM, 60 Hz

28.5 to 31.7 hp

Capacity F. A. D. @ 1770 RPM, 60 Hz

60.8 to 65.1 SCFM

Motor Rating @ 1170 RPM, 60 Hz

20 hp

Motor Rating @ 1770 RPM, 60 Hz

30 hp

Current @ 460 Volts @ 1170 RPM, 60 Hz

23.5 Amps

Current @ 460 Volts @ 1770 RPM, 60 Hz

34.4 Amps

Current @ 230 Volts @ 1770 RPM, 60 Hz

74 Amps

Current @ 230 Volts @ 1170 RPM, 60 Hz

68.8 Amps

Weight @ 1170 RPM, 60 Hz

1100 Pound

Weight @ 1770 RPM, 60 Hz

1100 Pound

Noise level @ 3 ft, 1170 RPM (60Hz)

82 dB(A)

Noise level @ 3 ft, 1770 RPM (60Hz)

86 dB(A)

Heat dissipation to water @ 1170 RRM, 60Hz

55,000 Btu/hr

Heat dissipation to water @ 1770 RRM, 60Hz

55,000 Btu/hr

Heat dissipation to ambient @ 1170 RRM, 60Hz

10,000 Btu/hr

Heat dissipation to ambient @ 1770 RRM, 60Hz

17,000 Btu/hr

Cooling Air Needed @ 1170 RPM, 60 Hz

6.1 GPM

Cooling Air Needed @ 1770 RPM, 60 Hz

9.2 GPM

Residual oil content at gas outlet (without filtration)

<5 mg/m³

Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz

27 ºF

Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz

31 ºF

Operational ambient temperature range

40-120 ºF

Oil Sump Capacity

9.5 Quarts

Overall Dimensions ( L x W x H )

53 X 28 X 33 Inch

Cooling Method

Water-Cooled

Drive Type

Direct Drive


Flow and Power

Power @ 145 PSIG, 1170 RPM, 60 Hz

19.1 hp

Flow @ 145 PSIG, 1170 RPM, 60 Hz

44.0 SCFM

Power @ 145 PSIG, 1770 RPM, 60 Hz

28.5 hp

Flow @ 145 PSIG, 1770 RPM, 60 Hz

65.1 SCFM

Power @ 290 PSIG, 1170 RPM, 60 Hz

20.2 hp

Flow @ 290 PSIG, 1170 RPM, 60 Hz

42.6 SCFM

Power @ 290 PSIG, 1770 RPM, 60 Hz

30.1 hp

Flow @ 290 PSIG, 1770 RPM, 60 Hz

62.9 SCFM

Power @ 435 PSIG, 1170 RPM, 60 Hz

21.3 hp

Flow @ 435 PSIG, 1170 RPM, 60 Hz

41.2 SCFM

Power @ 435 PSIG, 1770 RPM, 60 Hz

31.7 hp

Flow @ 435 PSIG, 1770 RPM, 60 Hz

60.8 SCFM


 DOWNLOADS 

 width= 2 Stage Water Cooled Performance Charts
(PDF, 81KB)


Request Information
  
 
 
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666