Sauer Compressors USA - Item # WP 200 Water Cooled Compressor
Home
2 Stage Air Cooled Compressors
up to 600 PSI
3 Stage Air Cooled Compressors
up to 1015 PSI
4 Stage Air Cooled Compressors
up to 6000 PSIs
2 Stage Water Cooled Compressors
up to 450 PSI
4 Stage Water Cooled Compressors
up to 5075 PSI
Boosters and Gas Compressors
Customized Solutions
Conversion Calculator
Sitemap
Request for Quote
Search Catalog
By Keyword
By Item #
All Categories
2 Stage Water Cooled Compressors up to 450 PSI
All Categories
>
Boosters and Gas Compressors
>
3 Stage Air Cooled Compressors up to 1015 PSI
>
2 Stage Water Cooled Compressors up to 450 PSI
>
Item # WP 200 Water Cooled Compressor
Download PDF
Printable Page
Email This Page
Save To Favorites
Item # WP 200 Water Cooled Compressor
Download PDF
Email This Page
Save To Favorites
larger image
The Alternative to Air-Cooled Compressors
With over 75 years of commercial and naval experience, Sauer Compressors hasdeveloped a series of highly competitive, robust, water-cooled compressors. Theseunits are ideal for industrial applications where airflow, high ambient temperatures,and/or ambient noise pose operational difficulties.
Specifications
·
Flow and Power
Specifications
Stages/Cylinders
2/2
Operating Pressure Range
100 to 435 psi
Required Power @ 1150 RPM, 60 Hz
31.4 to 34.9 hp
Capacity F. A. D. @ 1150 RPM, 60 Hz
70.8 to 75.8 SCFM
Required Power @ 1770 RPM, 60 Hz
47.8 to 53.1 hp
Capacity F. A. D. @ 1770 RPM, 60 Hz
103 to 110 SCFM
Motor Rating @ 1170 RPM, 60 Hz
40 hp
Motor Rating @ 1770 RPM, 60 Hz
60 hp
Current @ 460 Volts @ 1170 RPM, 60 Hz
47.1 Amps
Current @ 460 Volts @ 1770 RPM, 60 Hz
67 Amps
Current @ 230 Volts @ 1770 RPM, 60 Hz
94.2 Amps
Current @ 230 Volts @ 1170 RPM, 60 Hz
134 Amps
Weight @ 1170 RPM, 60 Hz
1826 Pound
Weight @ 1770 RPM, 60 Hz
1826 Pound
Noise level @ 3 ft, 1170 RPM (60Hz)
84 dB(A)
Noise level @ 3 ft, 1770 RPM (60Hz)
89 dB(A)
Heat dissipation to water @ 1170 RRM, 60Hz
78,000 Btu/hr
Heat dissipation to water @ 1770 RRM, 60Hz
133,000 Btu/hr
Heat dissipation to ambient @ 1170 RRM, 60Hz
17,000 Btu/hr
Heat dissipation to ambient @ 1770 RRM, 60Hz
31,000 Btu/hr
Cooling Air Needed @ 1170 RPM, 60 Hz
9.2 GPM
Cooling Air Needed @ 1770 RPM, 60 Hz
15.1 GPM
Residual oil content at gas outlet (without filtration)
<5 mg/m³
Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz
25 ºF
Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz
36 ºF
Operational ambient temperature range
40-120 ºF
Oil Sump Capacity
12.2 Quarts
Overall Dimensions ( L x W x H )
67 X 40 X 35 Inch
Cooling Method
Water-Cooled
Drive Type
Direct Drive
Flow and Power
Power @ 145 PSIG, 1170 RPM, 60 Hz
31.4 hp
Flow @ 145 PSIG, 1170 RPM, 60 Hz
75.8 SCFM
Power @ 145 PSIG, 1770 RPM, 60 Hz
47.8 hp
Flow @ 145 PSIG, 1770 RPM, 60 Hz
110.2 SCFM
Power @ 290 PSIG, 1170 RPM, 60 Hz
33.1 hp
Flow @ 290 PSIG, 1170 RPM, 60 Hz
73.3 SCFM
Power @ 290 PSIG, 1770 RPM, 60 Hz
50.4 hp
Flow @ 290 PSIG, 1770 RPM, 60 Hz
106.6 SCFM
Power @ 435 PSIG, 1170 RPM, 60 Hz
34.9 hp
Flow @ 435 PSIG, 1170 RPM, 60 Hz
70.8 SCFM
Power @ 435 PSIG, 1770 RPM, 60 Hz
53.1 hp
Flow @ 435 PSIG, 1770 RPM, 60 Hz
103.0 SCFM
DOWNLOADS
2 Stage Water Cooled Performance Charts
(PDF, 81KB)
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666