Item # WP 240 Water Cooled Compressor on Sauer Compressors USA Sauer Compressors USA - Item # WP 240 Water Cooled Compressor
      
 
Home About Us Products E-Newsletter Brochures Contact Us
  
 
Sauer Compressors
Customize your Sauer Compressor here!!!

 

Sauer Compressors
Search Catalog 
      GO   
 All Categories    2 Stage Water Cooled Compressors up to 450 PSI
Visit Us at our Booth!
All Categories > Boosters and Gas Compressors > 2 Stage Air Cooled Compressors up to 600 PSI > 3 Stage Air Cooled Compressors up to 1015 PSI > 4 Stage Air Cooled Compressors up to 6000 PSI > 2 Stage Water Cooled Compressors up to 450 PSI > Item # WP 240 Water Cooled Compressor  
    Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # WP 240 Water Cooled Compressor



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

2-Stage-water-cooled

larger image
The Alternative to Air-Cooled Compressors
With over 75 years of commercial and naval experience, Sauer Compressors hasdeveloped a series of highly competitive, robust, water-cooled compressors. Theseunits are ideal for industrial applications where airflow, high ambient temperatures,and/or ambient noise pose operational difficulties.




Specifications · Flow and Power

Specifications

Stages/Cylinders

2/2

Operating Pressure Range

100 to 435 psi

Required Power @ 1150 RPM, 60 Hz

38.8 to 43.1 hp

Capacity F. A. D. @ 1150 RPM, 60 Hz

86 to 92.4 SCFM

Required Power @ 1770 RPM, 60 Hz

58.8 to 65.4 hp

Capacity F. A. D. @ 1770 RPM, 60 Hz

124 to 133.5 SCFM

Motor Rating @ 1170 RPM, 60 Hz

40 hp

Motor Rating @ 1770 RPM, 60 Hz

60 hp

Current @ 460 Volts @ 1170 RPM, 60 Hz

47.1 Amps

Current @ 460 Volts @ 1770 RPM, 60 Hz

67 Amps

Current @ 230 Volts @ 1770 RPM, 60 Hz

94.2 Amps

Current @ 230 Volts @ 1170 RPM, 60 Hz

134 Amps

Weight @ 1170 RPM, 60 Hz

1870 Pound

Weight @ 1770 RPM, 60 Hz

1870 Pound

Noise level @ 3 ft, 1170 RPM (60Hz)

84 dB(A)

Noise level @ 3 ft, 1770 RPM (60Hz)

89 dB(A)

Heat dissipation to water @ 1170 RRM, 60Hz

109,000 Btu/hr

Heat dissipation to water @ 1770 RRM, 60Hz

160,000 Btu/hr

Heat dissipation to ambient @ 1170 RRM, 60Hz

24,000 Btu/hr

Heat dissipation to ambient @ 1770 RRM, 60Hz

34,000 Btu/hr

Cooling Air Needed @ 1170 RPM, 60 Hz

12.4 GPM

Cooling Air Needed @ 1770 RPM, 60 Hz

18.2 GPM

Residual oil content at gas outlet (without filtration)

<5 mg/m³

Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz

45 ºF

Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz

59 ºF

Operational ambient temperature range

40-120 ºF

Oil Sump Capacity

12.2 Quarts

Overall Dimensions ( L x W x H )

60 X 40 X 35 Inch

Cooling Method

Water-Cooled

Drive Type

Direct Drive


Flow and Power

Power @ 145 PSIG, 1170 RPM, 60 Hz

38.8 hp

Flow @ 145 PSIG, 1170 RPM, 60 Hz

92.0 SCFM

Power @ 145 PSIG, 1770 RPM, 60 Hz

58.8 hp

Flow @ 145 PSIG, 1770 RPM, 60 Hz

133.5 SCFM

Power @ 290 PSIG, 1170 RPM, 60 Hz

40.9 hp

Flow @ 290 PSIG, 1170 RPM, 60 Hz

89.0 SCFM

Power @ 290 PSIG, 1770 RPM, 60 Hz

62.1 hp

Flow @ 290 PSIG, 1770 RPM, 60 Hz

129.1 SCFM

Power @ 435 PSIG, 1170 RPM, 60 Hz

43.1 hp

Flow @ 435 PSIG, 1170 RPM, 60 Hz

86.0 SCFM

Power @ 435 PSIG, 1770 RPM, 60 Hz

65.4 hp

Flow @ 435 PSIG, 1770 RPM, 60 Hz

124.8 SCFM


 DOWNLOADS 

 width= 2 Stage Water Cooled Performance Charts
(PDF, 81KB)


Request Information
  
 
 
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666
Phone: 410-604-3142 | Fax: 410-604-3209 | Email:
 
  
Join our Mailing List