Item # WP 240 Water Cooled Compressor on Sauer Compressors USA
Sauer Compressors USA - Item # WP 240 Water Cooled Compressor
Home
2 Stage Air Cooled Compressors
up to 600 PSI
3 Stage Air Cooled Compressors
up to 1015 PSI
4 Stage Air Cooled Compressors
up to 6000 PSI
2 Stage Water Cooled Compressors
up to 450 PSI
4 Stage Water Cooled Compressors
up to 5075 PSI
Boosters and Gas Compressors
Customized Solutions
Conversion Calculator
Sitemap
Request for Quote
Download the Sauer Compressors USA Survey (PDF)
Search Catalog
By Keyword
By Item #
All Categories
2 Stage Water Cooled Compressors up to 450 PSI
All Categories
>
Boosters and Gas Compressors
>
2 Stage Air Cooled Compressors up to 600 PSI
>
3 Stage Air Cooled Compressors up to 1015 PSI
>
4 Stage Air Cooled Compressors up to 6000 PSI
>
2 Stage Water Cooled Compressors up to 450 PSI
>
Item # WP 240 Water Cooled Compressor
Download PDF
Printable Page
Email This Page
Save To Favorites
Item # WP 240 Water Cooled Compressor
Download PDF
Email This Page
Save To Favorites
larger image
The Alternative to Air-Cooled Compressors
With over 75 years of commercial and naval experience, Sauer Compressors hasdeveloped a series of highly competitive, robust, water-cooled compressors. Theseunits are ideal for industrial applications where airflow, high ambient temperatures,and/or ambient noise pose operational difficulties.
Specifications
·
Flow and Power
Specifications
Stages/Cylinders
2/2
Operating Pressure Range
100 to 435 psi
Required Power @ 1150 RPM, 60 Hz
38.8 to 43.1 hp
Capacity F. A. D. @ 1150 RPM, 60 Hz
86 to 92.4 SCFM
Required Power @ 1770 RPM, 60 Hz
58.8 to 65.4 hp
Capacity F. A. D. @ 1770 RPM, 60 Hz
124 to 133.5 SCFM
Motor Rating @ 1170 RPM, 60 Hz
40 hp
Motor Rating @ 1770 RPM, 60 Hz
60 hp
Current @ 460 Volts @ 1170 RPM, 60 Hz
47.1 Amps
Current @ 460 Volts @ 1770 RPM, 60 Hz
67 Amps
Current @ 230 Volts @ 1770 RPM, 60 Hz
94.2 Amps
Current @ 230 Volts @ 1170 RPM, 60 Hz
134 Amps
Weight @ 1170 RPM, 60 Hz
1870 Pound
Weight @ 1770 RPM, 60 Hz
1870 Pound
Noise level @ 3 ft, 1170 RPM (60Hz)
84 dB(A)
Noise level @ 3 ft, 1770 RPM (60Hz)
89 dB(A)
Heat dissipation to water @ 1170 RRM, 60Hz
109,000 Btu/hr
Heat dissipation to water @ 1770 RRM, 60Hz
160,000 Btu/hr
Heat dissipation to ambient @ 1170 RRM, 60Hz
24,000 Btu/hr
Heat dissipation to ambient @ 1770 RRM, 60Hz
34,000 Btu/hr
Cooling Air Needed @ 1170 RPM, 60 Hz
12.4 GPM
Cooling Air Needed @ 1770 RPM, 60 Hz
18.2 GPM
Residual oil content at gas outlet (without filtration)
<5 mg/m³
Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz
45 ºF
Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz
59 ºF
Operational ambient temperature range
40-120 ºF
Oil Sump Capacity
12.2 Quarts
Overall Dimensions ( L x W x H )
60 X 40 X 35 Inch
Cooling Method
Water-Cooled
Drive Type
Direct Drive
Flow and Power
Power @ 145 PSIG, 1170 RPM, 60 Hz
38.8 hp
Flow @ 145 PSIG, 1170 RPM, 60 Hz
92.0 SCFM
Power @ 145 PSIG, 1770 RPM, 60 Hz
58.8 hp
Flow @ 145 PSIG, 1770 RPM, 60 Hz
133.5 SCFM
Power @ 290 PSIG, 1170 RPM, 60 Hz
40.9 hp
Flow @ 290 PSIG, 1170 RPM, 60 Hz
89.0 SCFM
Power @ 290 PSIG, 1770 RPM, 60 Hz
62.1 hp
Flow @ 290 PSIG, 1770 RPM, 60 Hz
129.1 SCFM
Power @ 435 PSIG, 1170 RPM, 60 Hz
43.1 hp
Flow @ 435 PSIG, 1170 RPM, 60 Hz
86.0 SCFM
Power @ 435 PSIG, 1770 RPM, 60 Hz
65.4 hp
Flow @ 435 PSIG, 1770 RPM, 60 Hz
124.8 SCFM