The Alternative to Air-Cooled Compressors
With over 75 years of commercial and naval experience, Sauer Compressors hasdeveloped a series of highly competitive, robust, water-cooled compressors. Theseunits are ideal for industrial applications where airflow, high ambient temperatures,and/or ambient noise pose operational difficulties.




Specifications · Flow and Power

Specifications

Stages/Cylinders

2/3

Operating Pressure Range

100 to 435 psi

Required Power @ 1150 RPM, 60 Hz

63 to 70 hp

Capacity F. A. D. @ 1150 RPM, 60 Hz

153 to 164 SCFM

Required Power @ 1770 RPM, 60 Hz

98.4 to 109.3 hp

Capacity F. A. D. @ 1770 RPM, 60 Hz

217 to 231 SCFM

Motor Rating @ 1170 RPM, 60 Hz

70 hp

Motor Rating @ 1770 RPM, 60 Hz

125 hp

Current @ 460 Volts @ 1170 RPM, 60 Hz

86.8 Amps

Current @ 460 Volts @ 1770 RPM, 60 Hz

138 Amps

Current @ 230 Volts @ 1770 RPM, 60 Hz

173.3 Amps

Current @ 230 Volts @ 1170 RPM, 60 Hz

276 Amps

Weight @ 1170 RPM, 60 Hz

2970 Pound

Weight @ 1770 RPM, 60 Hz

2970 Pound

Noise level @ 3 ft, 1170 RPM (60Hz)

87 dB(A)

Noise level @ 3 ft, 1770 RPM (60Hz)

92 dB(A)

Heat dissipation to water @ 1170 RRM, 60Hz

160,000 Btu/hr

Heat dissipation to water @ 1770 RRM, 60Hz

266,000 Btu/hr

Heat dissipation to ambient @ 1170 RRM, 60Hz

34,000 Btu/hr

Heat dissipation to ambient @ 1770 RRM, 60Hz

58,000 Btu/hr

Cooling Air Needed @ 1170 RPM, 60 Hz

18.2 GPM

Cooling Air Needed @ 1770 RPM, 60 Hz

30.6 GPM

Residual oil content at gas outlet (without filtration)

<5 mg/m³

Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz

32 ºF

Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz

41 ºF

Operational ambient temperature range

40-120 ºF

Oil Sump Capacity

14.3 Quarts

Overall Dimensions ( L x W x H )

71 X 46 X 43 Inch

Cooling Method

Water-Cooled

Drive Type

Direct Drive


Flow and Power

Power @ 145 PSIG, 1170 RPM, 60 Hz

63.0 hp

Flow @ 145 PSIG, 1170 RPM, 60 Hz

164.0 SCFM

Power @ 145 PSIG, 1770 RPM, 60 Hz

98.4 hp

Flow @ 145 PSIG, 1770 RPM, 60 Hz

231.6 SCFM

Power @ 290 PSIG, 1170 RPM, 60 Hz

66.5 hp

Flow @ 290 PSIG, 1170 RPM, 60 Hz

158.6 SCFM

Power @ 290 PSIG, 1770 RPM, 60 Hz

103.8 hp

Flow @ 290 PSIG, 1770 RPM, 60 Hz

224.0 SCFM

Power @ 435 PSIG, 1170 RPM, 60 Hz

70.0 hp

Flow @ 435 PSIG, 1170 RPM, 60 Hz

153.3 SCFM

Power @ 435 PSIG, 1770 RPM, 60 Hz

109.3 hp

Flow @ 435 PSIG, 1770 RPM, 60 Hz

216.5 SCFM


 DOWNLOADS 

 width= 2 Stage Water Cooled Performance Charts
(PDF, 81KB)


Request Information
  
 
 
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666