Sauer Compressors USA - Item # WP 126L Air Cooled Compressor
      
 
Home About Us Products News Contact Us
  
 
Sauer Compressors
Customize your Sauer Compressor here!!!
Sauer Compressors
Search Catalog 
      GO   
 All Categories    3 Stage Air Cooled Compressors up to 1015 PSI
Visit Us at the HydroVision International!
All Categories > 4 Stage Air Cooled Compressors up to 6000 PSI > 3 Stage Air Cooled Compressors up to 1015 PSI > Item # WP 126L Air Cooled Compressor  
    Download PDF Download PDF     Print Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # WP 126L Air Cooled Compressor



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

3-stage-air-cooled

larger image
The Sauer 3-stage compressor demonstrates exceptional endurance even under the most difficult operatingconditions. The 3-stage design lowers cylinder compression temperatures, and reduces the pressure ratioper cylinder. This feature promotes lower maintenance costs and improves unit longevity and reliability.



Specifications · Flow and Power

Specifications

Stages/Cylinders

3/3

Operating Pressure Range

580 to 1160 psi

Required Power @ 1150 RPM, 60 Hz

33.8 to 35.5 hp

Capacity F. A. D. @ 1150 RPM, 60 Hz

53.2 to 53.5 SCFM

Required Power @ 1770 RPM, 60 Hz

43.6 to 46.9 hp

Capacity F. A. D. @ 1770 RPM, 60 Hz

75.9 to 77.1 SCFM

Motor Rating @ 1170 RPM, 60 Hz

40 hp

Motor Rating @ 1770 RPM, 60 Hz

50 hp

Current @ 460 Volts @ 1170 RPM, 60 Hz

47.1 Amps

Current @ 460 Volts @ 1770 RPM, 60 Hz

57.8 Amps

Current @ 230 Volts @ 1170 RPM, 60 Hz

94.2 Amps

Current @ 230 Volts @ 1770 RPM, 60 Hz

115.6 Amps

Weight @ 1170 RPM, 60 Hz

1441 Pound

Weight @ 1770 RPM, 60 Hz

1441 Pound

Noise level @ 3 ft, 1170 RPM (60Hz)

87 dB(A)

Noise level @ 3 ft, 1770 RPM (60Hz)

92 dB(A)

Heat Dissipation @ 1170 RPM, 60 Hz

82,000 Btu/hr

Heat Dissipation @ 1770 RPM, 60 Hz

102,000 Btu/hr

Cooling Air Needed @ 1170 RPM, 60 Hz

3,060 CFM

Cooling Air Needed @ 1770 RPM, 60 Hz

4,120 CFM

Residual oil content at gas outlet (without filtration)

<5 mg/m³

Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz

32 ºF

Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz

47 ºF

Operational ambient temperature range

40-130 ºF

Oil Sump Capacity

14.4 Quarts

Overall Dimensions ( L x W x H )

62 X 38 X 41 Inch

Cooling Method

Air-Cooled

Drive Type

Direct Drive


Flow and Power

Power @ 725 PSIG, 1170 RPM, 60 Hz

33.8 hp

Flow @ 725 PSIG, 1170 RPM, 60 Hz

53.2 SCFM

Power @ 725 PSIG, 1770 RPM, 60 Hz

43.6 hp

Flow @ 725 PSIG, 1770 RPM, 60 Hz

77.1 SCFM

Power @ 1015 PSIG, 1170 RPM, 60 Hz

35.3 hp

Flow @ 1015 PSIG, 1170 RPM, 60 Hz

53.5 SCFM

Power @ 1015 PSIG, 1770 RPM, 60 Hz

46.9 hp

Flow @ 1015 PSIG, 1770 RPM, 60 Hz

79.4 SCFM

Power @ 1160 PSIG, 1170 RPM, 60 Hz

35.5 hp

Flow @ 1160 PSIG, 1170 RPM, 60 Hz

53.5 SCFM

Power @ 1160 PSIG, 1770 RPM, 60 Hz

46.9 hp

Flow @ 1160 PSIG, 1770 RPM, 60 Hz

75.9 SCFM


 DOWNLOADS 

 width= 3 and 4 Stage Air Cooled Performance Charts
(PDF, 77KB)

 width= 3 Stage Air Cooled Performance Charts
(PDF, 76KB)


Request Information
  
 
 