3 Stage Air Cooled Compressors up to 1015 PSI
All Categories
>
Boosters and Gas Compressors
>
2 Stage Air Cooled Compressors up to 600 PSI
>
3 Stage Air Cooled Compressors up to 1015 PSI
>
Item # WP 311L Air Cooled Compressor
Download PDF
Printable Page
Email This Page
Save To Favorites
Item # WP 311L Air Cooled Compressor
Download PDF
Email This Page
Save To Favorites
larger image
The Sauer 3-stage compressor demonstrates exceptional endurance even under the most difficult operatingconditions. The 3-stage design lowers cylinder compression temperatures, and reduces the pressure ratioper cylinder. This feature promotes lower maintenance costs and improves unit longevity and reliability.
Specifications
·
Flow and Power
Specifications
Stages/Cylinders
3/4
Operating Pressure Range
200 to 640 psi
Required Power @ 1150 RPM, 60 Hz
49.8 to 58.1 hp
Capacity F. A. D. @ 1150 RPM, 60 Hz
125.1 to 136 SCFM
Required Power @ 1770 RPM, 60 Hz
85.2 to 102.4 hp
Capacity F. A. D. @ 1770 RPM, 60 Hz
184 to 207.7 SCFM
Motor Rating @ 1170 RPM, 60 Hz
60 hp
Motor Rating @ 1770 RPM, 60 Hz
125 hp
Current @ 460 Volts @ 1170 RPM, 60 Hz
70.1 Amps
Current @ 460 Volts @ 1770 RPM, 60 Hz
138 Amps
Current @ 230 Volts @ 1170 RPM, 60 Hz
140.2 Amps
Current @ 230 Volts @ 1770 RPM, 60 Hz
276 Amps
Weight @ 1170 RPM, 60 Hz
2365 Pound
Weight @ 1770 RPM, 60 Hz
2365 Pound
Noise level @ 3 ft, 1170 RPM (60Hz)
91 dB(A)
Noise level @ 3 ft, 1770 RPM (60Hz)
96 dB(A)
Heat Dissipation @ 1170 RPM, 60 Hz
164,000 Btu/hr
Heat Dissipation @ 1770 RPM, 60 Hz
328,000 Btu/hr
Cooling Air Needed @ 1170 RPM, 60 Hz
5,060 CFM
Cooling Air Needed @ 1770 RPM, 60 Hz
10,240 CFM
Residual oil content at gas outlet (without filtration)
<5 mg/m³
Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz
27 ºF
Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz
43 ºF
Operational ambient temperature range
40-130 ºF
Oil Sump Capacity
22.7 Quarts
Overall Dimensions ( L x W x H )
72 X 42 X 43 Inch
Cooling Method
Air-Cooled
Drive Type
Direct Drive
Flow and Power
Power @ 290 PSIG, 1170 RPM, 60 Hz
52.6 hp
Flow @ 290 PSIG, 1170 RPM, 60 Hz
131.8 SCFM
Power @ 290 PSIG, 1770 RPM, 60 Hz
89.9 hp
Flow @ 290 PSIG, 1770 RPM, 60 Hz
200.9 SCFM
Power @ 435 PSIG, 1170 RPM, 60 Hz
55.4 hp
Flow @ 435 PSIG, 1170 RPM, 60 Hz
127.4 SCFM
Power @ 435 PSIG, 1770 RPM, 60 Hz
94.6 hp
Flow @ 435 PSIG, 1770 RPM, 60 Hz
194.1 SCFM
Power @ 580 PSIG, 1170 RPM, 60 Hz
58.1 hp
Flow @ 580 PSIG, 1170 RPM, 60 Hz
15.9 SCFM
Power @ 580 PSIG,1770 RPM, 60 Hz
102.4 hp
Flow @ 580 PSIG, 1770 RPM, 60 Hz
184.1 SCFM