Sauer Compressors USA - Item # WP 311L Air Cooled Compressor
      
 
Home About Us Products News Contact Us
  
 
Sauer Compressors
Customize your Sauer Compressor here!!!
Sauer Compressors
Search Catalog 
      GO   
 All Categories    3 Stage Air Cooled Compressors up to 1015 PSI
Visit Us at the HydroVision International!
All Categories > 4 Stage Air Cooled Compressors up to 6000 PSI > 3 Stage Air Cooled Compressors up to 1015 PSI > Item # WP 311L Air Cooled Compressor  
    Download PDF Download PDF     Print Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # WP 311L Air Cooled Compressor



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

3-stage-air-cooled

larger image
The Sauer 3-stage compressor demonstrates exceptional endurance even under the most difficult operatingconditions. The 3-stage design lowers cylinder compression temperatures, and reduces the pressure ratioper cylinder. This feature promotes lower maintenance costs and improves unit longevity and reliability.



Specifications · Flow and Power

Specifications

Stages/Cylinders

3/4

Operating Pressure Range

200 to 640 psi

Required Power @ 1150 RPM, 60 Hz

49.8 to 58.1 hp

Capacity F. A. D. @ 1150 RPM, 60 Hz

125.1 to 136 SCFM

Required Power @ 1770 RPM, 60 Hz

85.2 to 102.4 hp

Capacity F. A. D. @ 1770 RPM, 60 Hz

184 to 207.7 SCFM

Motor Rating @ 1170 RPM, 60 Hz

60 hp

Motor Rating @ 1770 RPM, 60 Hz

125 hp

Current @ 460 Volts @ 1170 RPM, 60 Hz

70.1 Amps

Current @ 460 Volts @ 1770 RPM, 60 Hz

138 Amps

Current @ 230 Volts @ 1170 RPM, 60 Hz

140.2 Amps

Current @ 230 Volts @ 1770 RPM, 60 Hz

276 Amps

Weight @ 1170 RPM, 60 Hz

2365 Pound

Weight @ 1770 RPM, 60 Hz

2365 Pound

Noise level @ 3 ft, 1170 RPM (60Hz)

91 dB(A)

Noise level @ 3 ft, 1770 RPM (60Hz)

96 dB(A)

Heat Dissipation @ 1170 RPM, 60 Hz

164,000 Btu/hr

Heat Dissipation @ 1770 RPM, 60 Hz

328,000 Btu/hr

Cooling Air Needed @ 1170 RPM, 60 Hz

5,060 CFM

Cooling Air Needed @ 1770 RPM, 60 Hz

10,240 CFM

Residual oil content at gas outlet (without filtration)

<5 mg/m³

Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz

27 ºF

Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz

43 ºF

Operational ambient temperature range

40-130 ºF

Oil Sump Capacity

22.7 Quarts

Overall Dimensions ( L x W x H )

72 X 42 X 43 Inch

Cooling Method

Air-Cooled

Drive Type

Direct Drive


Flow and Power

Power @ 290 PSIG, 1170 RPM, 60 Hz

52.6 hp

Flow @ 290 PSIG, 1170 RPM, 60 Hz

131.8 SCFM

Power @ 290 PSIG, 1770 RPM, 60 Hz

89.9 hp

Flow @ 290 PSIG, 1770 RPM, 60 Hz

200.9 SCFM

Power @ 435 PSIG, 1170 RPM, 60 Hz

55.4 hp

Flow @ 435 PSIG, 1170 RPM, 60 Hz

127.4 SCFM

Power @ 435 PSIG, 1770 RPM, 60 Hz

94.6 hp

Flow @ 435 PSIG, 1770 RPM, 60 Hz

194.1 SCFM

Power @ 580 PSIG, 1170 RPM, 60 Hz

58.1 hp

Flow @ 580 PSIG, 1170 RPM, 60 Hz

15.9 SCFM

Power @ 580 PSIG,1770 RPM, 60 Hz

102.4 hp

Flow @ 580 PSIG, 1770 RPM, 60 Hz

184.1 SCFM


 DOWNLOADS 

 width= 3 and 4 Stage Air Cooled Performance Charts
(PDF, 77KB)

 width= 3 Stage Air Cooled Performance Charts
(PDF, 76KB)


Request Information
  
 
 
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666