Sauer Compressors USA - Item # WP 3215 Air Cooled Compressor
Home
2 Stage Air Cooled Compressors
up to 600 PSI
3 Stage Air Cooled Compressors
up to 1015 PSI
4 Stage Air Cooled Compressors
up to 6000 PSIs
2 Stage Water Cooled Compressors
up to 450 PSI
4 Stage Water Cooled Compressors
up to 5075 PSI
Boosters and Gas Compressors
Customized Solutions
Conversion Calculator
Sitemap
Request for Quote
Search Catalog
By Keyword
By Item #
All Categories
3 Stage Air Cooled Compressors up to 1015 PSI
All Categories
>
4 Stage Air Cooled Compressors up to 6000 PSI
>
4 Stage Water Cooled Compressors up to 5075 PSI
>
2 Stage Air Cooled Compressors up to 600 PSI
>
3 Stage Air Cooled Compressors up to 1015 PSI
>
Item # WP 3215 Air Cooled Compressor
Download PDF
Printable Page
Email This Page
Save To Favorites
Item # WP 3215 Air Cooled Compressor
Download PDF
Email This Page
Save To Favorites
larger image
The Sauer 3-stage compressor demonstrates exceptional endurance even under the most difficult operatingconditions. The 3-stage design lowers cylinder compression temperatures, and reduces the pressure ratioper cylinder. This feature promotes lower maintenance costs and improves unit longevity and reliability.
Specifications
·
Flow and Power
Specifications
Stages/Cylinders
3/3
Operating Pressure Range
1450 to 5075 psi
Required Power @ 1150 RPM, 60 Hz
5.1 to 6 hp
Capacity F. A. D. @ 1150 RPM, 60 Hz
6.4 to 7.4 SCFM
Required Power @ 1770 RPM, 60 Hz
10.3 to 11.7 hp
Capacity F. A. D. @ 1770 RPM, 60 Hz
9.8 to 11.2 SCFM
Motor Rating @ 1170 RPM, 60 Hz
7.5 (4.8KW) hp
Motor Rating @ 1770 RPM, 60 Hz
10 (8.7KW) hp
Current @ 460 Volts @ 1170 RPM, 60 Hz
10 Amps
Current @ 460 Volts @ 1770 RPM, 60 Hz
14.4 Amps
Current @ 230 Volts @ 1170 RPM, 60 Hz
20 Amps
Current @ 230 Volts @ 1770 RPM, 60 Hz
28.8 Amps
Weight @ 1170 RPM, 60 Hz
1152.8 Pound
Weight @ 1770 RPM, 60 Hz
1152.8 Pound
Noise level @ 3 ft, 1170 RPM (60Hz)
71 dB(A)
Noise level @ 3 ft, 1770 RPM (60Hz)
72 dB(A)
Heat Dissipation @ 1170 RPM, 60 Hz
20,000 Btu/hr
Heat Dissipation @ 1770 RPM, 60 Hz
34,000 Btu/hr
Cooling Air Needed @ 1170 RPM, 60 Hz
590 CFM
Cooling Air Needed @ 1770 RPM, 60 Hz
1,000 CFM
Residual oil content at gas outlet (without filtration)
<3 mg/m³
Delta temperature (gas oultet vs. ambient) @ 1170 RPM, 60 Hz
18 ºF
Delta temperature (gas oultet vs. ambient) @ 1770 RPM, 60 Hz
18 ºF
Operational ambient temperature range
40-110 ºF
Oil Sump Capacity
6.1 Quarts
Overall Dimensions ( L x W x H )
60 X 30 X 62 Inch
Cooling Method
Air-Cooled
Drive Type
Direct Drive
Flow and Power
Power @ 1450 PSIG, 1170 RPM, 60 Hz
5.1 hp
Flow @ 1450 PSIG, 1170 RPM, 60 Hz
7.4 SCFM
Power @ 1450 PSIG, 1770 RPM, 60 Hz
10.3 hp
Flow @ 1450 PSIG, 1770 RPM, 60 Hz
11.2 SCFM
Power @ 2900 PSIG, 1170 RPM, 60 Hz
5.5 hp
Flow @ 2900 PSIG, 1170 RPM, 60 Hz
7.0 SCFM
Power @ 2900 PSIG, 1770 RPM, 60 Hz
10.9 hp
Flow @ 2900 PSIG, 1770 RPM, 60 Hz
10.7 SCFM
Power @ 4350 PSIG, 1170 RPM, 60 Hz
5.9 hp
Flow @ 4350 PSIG, 1170 RPM, 60 Hz
6.6 SCFM
Power @ 4350 PSIG, 1770 RPM, 60 Hz
11.4 hp
Flow @ 4350 PSIG, 1770 RPM, 60 Hz
10.0 SCFM
Power @ 5075 PSIG, 1170 RPM, 60 Hz
6.0 hp
Power @ 5075 PSIG, 1770 RPM, 60 Hz
6.4 hp
Flow @ 5075 PSIG, 1170 RPM, 60 Hz
11.7 SCFM
Flow @ 5075 PSIG, 1770 RPM, 60 Hz
9.8 SCFM
DOWNLOADS
3 and 4 Stage Air Cooled Performance Charts
(PDF, 77KB)
3 Stage Air Cooled Performance Charts
(PDF, 76KB)
Sauer Compressors USA, Inc. · 64 Log Canoe Circle · Stevensville · MD 21666