Hurricane Series Compressors are used for Air or Nitrogen compression. Each compressor is an air-cooled, single acting, four stage, reciprocating piston compressor with the combination of oil pressure fed crankshaft bearings, and cylinder oil splash with regulated injection for the final high-pressure piston plunger design. Performance with inert gases, such as Nitrogen.
Stages/Cylinders |
N/A 4 Stages |
Models |
N/A WP4331, WP4341, WP4351 |
Operating Pressure Range |
N/A 1750 to 5800 psi |
Required Power |
N/A 20 to 75 hp |
Flow Rate |
N/A 18 to 70 SCFM |
Multi-stage oil-lubricated piston compressor |
N/A Standard |
Inter-stage and final after-cooler with oil/water separators |
N/A Standard |
Over-pressure saftey valves at each stage |
N/A Standard |
Gas-tight over-pressure safety valves at each stage (piped exit, manifold) |
N/A Optional |
Automatic oil/water drain valves |
N/A Standard |
Auto-starting relief integrated with drain system |
N/A Standard |
Pressure indicator at each stage |
N/A Optional |
Gas over-temperature protective shutdown sensor |
N/A Standard |
Oil lubrication including protection sensor |
N/A Optional |
Pressure and temperature indicators and sensor-switch at all stages |
N/A Standard |
Air-blast cooling fan and flywheel |
N/A Standard |
Lubricating oil level alarm |
N/A Standard |
Gas suction connection (flange, pipe) |
N/A Standard |
Crankcase oil sump heating |
N/A Optional |
Flexible drive coupling |
N/A Standard |
Direct drive Electric Motor |
N/A Standard |
Direct-drive Ex-motor (ATEX) |
N/A Optional |
Resilient AV mounts |
N/A Standard |
Outlet flexible hose with non-return valve |
N/A Standard |
Flexible oil/water drain hose |
N/A Standard |
Auto Start-Stop pressure sensor control |
N/A Standard |
Oil/water drain gas seprator ‘Demister’ vessel |
N/A Optional |
Oil/water collection tank |
N/A Optional |
Oil/water collection tank (level alarm) |
N/A Optional |
Electrical Control Panel (Safe Area, Start/Stop, alarms, shutdowns) |
N/A Optional |
Acoustic enclosure - internal heater, fan ventilation, gas detection |
N/A Optional |
Ex-proof drive coupling (ATEX 95) |
N/A Optional |
Anti-static air-blast cooling fan (ATEX 95) |
N/A Optional |
Electrical Control panel to ATEX zone 1 and 2 |
N/A Optional |
Supply gas pressure sensor control (Auto-Stop/Restart) |
N/A Optional |
Supply gas isolating valve (manual, solenoid, actuator, electrical inter-lock) |
N/A Optional |
In-line gas suction filter |
N/A Optional |
Suction gas regulation (pressure reducing valve) |
N/A Optional |
Suction gas shut-off valve (solenoid, actuated) |
N/A Optional |
Capacity control (re-cycling by-pass valve, discharge back to suction) |
N/A Optional |
Inlet gas pulsation damper (suction 'buffer tank' inc. drain/purge valve) |
N/A Optional |
Suction gas protection (safety valve, pressure gauge, high/low pressure sensor-switch) |
N/A Optional |
Flexible suction gas hose |
N/A Optional |
Outlet oil coalescing filtration (manual, auto drain) |
N/A Optional |
Outlet oil vapour activated carbon filtration (manual drain) |
N/A Optional |
Outlet purge connection |
N/A Optional |
Final Pressure Maintaining Valve |
N/A Optional |
Gas drying (suction, outlet HP Dryer) |
N/A Optional |
Auto Stop/Start pressure sensor control |
N/A Optional |