Hurricane Series Compressors are used for Air or Nitrogen compression. Each compressor is an air-cooled, single acting, four stage, reciprocating piston compressor with the combination of oil pressure fed crankshaft bearings, and cylinder oil splash with regulated injection for the final high-pressure piston plunger design. Performance with inert gases, such as Nitrogen.

Unit of Measure

Specifications

Stages/Cylinders

N/A 4 Stages

Models

N/A WP4331, WP4341, WP4351

Operating Pressure Range

N/A 1750 to 5800 psi

Required Power

N/A 20 to 75 hp

Flow Rate

N/A 18 to 70 SCFM

Features

Multi-stage oil-lubricated piston compressor

N/A Standard

Inter-stage and final after-cooler with oil/water separators

N/A Standard

Over-pressure saftey valves at each stage

N/A Standard

Gas-tight over-pressure safety valves at each stage (piped exit, manifold)

N/A Optional

Automatic oil/water drain valves

N/A Standard

Auto-starting relief integrated with drain system

N/A Standard

Pressure indicator at each stage

N/A Optional

Gas over-temperature protective shutdown sensor

N/A Standard

Oil lubrication including protection sensor

N/A Optional

Pressure and temperature indicators and sensor-switch at all stages

N/A Standard

Air-blast cooling fan and flywheel

N/A Standard

Lubricating oil level alarm

N/A Standard

Gas suction connection (flange, pipe)

N/A Standard

Crankcase oil sump heating

N/A Optional

Flexible drive coupling

N/A Standard

Direct drive Electric Motor

N/A Standard

Direct-drive Ex-motor (ATEX)

N/A Optional

Resilient AV mounts

N/A Standard

Outlet flexible hose with non-return valve

N/A Standard

Flexible oil/water drain hose

N/A Standard

Auto Start-Stop pressure sensor control

N/A Standard

Oil/water drain gas seprator ‘Demister’ vessel

N/A Optional

Oil/water collection tank

N/A Optional

Oil/water collection tank (level alarm)

N/A Optional

Electrical Control Panel (Safe Area, Start/Stop, alarms, shutdowns)

N/A Optional

Acoustic enclosure - internal heater, fan ventilation, gas detection

N/A Optional

Ex-proof drive coupling (ATEX 95)

N/A Optional

Anti-static air-blast cooling fan (ATEX 95)

N/A Optional

Electrical Control panel to ATEX zone 1 and 2

N/A Optional

Supply gas pressure sensor control (Auto-Stop/Restart)

N/A Optional

Supply gas isolating valve (manual, solenoid, actuator, electrical inter-lock)

N/A Optional

In-line gas suction filter

N/A Optional

Suction gas regulation (pressure reducing valve)

N/A Optional

Suction gas shut-off valve (solenoid, actuated)

N/A Optional

Capacity control (re-cycling by-pass valve, discharge back to suction)

N/A Optional

Inlet gas pulsation damper (suction 'buffer tank' inc. drain/purge valve)

N/A Optional

Suction gas protection (safety valve, pressure gauge, high/low pressure sensor-switch)

N/A Optional

Flexible suction gas hose

N/A Optional

Outlet oil coalescing filtration (manual, auto drain)

N/A Optional

Outlet oil vapour activated carbon filtration (manual drain)

N/A Optional

Outlet purge connection

N/A Optional

Final Pressure Maintaining Valve

N/A Optional

Gas drying (suction, outlet HP Dryer)

N/A Optional

Auto Stop/Start pressure sensor control

N/A Optional