Stages/Cylinders |
N/A 3 Stages |
Models |
N/A WP151, WP271L, WP311L, WP66L, WP126L, WP206L WP81L, WP101L, WP121L |
Operating Pressure Range |
N/A 150 to 1150 psi |
Required Power |
N/A 20 to 100 hp |
Flow Rate |
N/A 39 to 178 SCFM |
Multi-stage oil-lubricated piston compressor |
N/A Standard |
Inter-stage and final after-cooler with oil/water separators |
N/A Standard |
Over-pressure saftey valves at each stage |
N/A Standard |
Gas-tight over-pressure safety valves at each stage (piped exit, manifold) |
N/A Standard |
Automatic oil/water drain valves |
N/A Standard |
Auto-starting relief integrated with drain system |
N/A Standard |
Pressure indicator at each stage |
N/A Standard |
Gas over-temperature protective shutdown sensor |
N/A Standard |
Oil lubrication including protection sensor |
N/A Standard |
Pressure and temperature indicators and sensor-switch at all stages |
N/A Optional |
Air-blast cooling fan and flywheel |
N/A Standard |
Lubricating oil level alarm |
N/A Optional |
Gas suction connection (flange, pipe) |
N/A Standard |
Crankcase oil sump heating |
N/A Optional with Non-Explosion Proof Model only, Not available in Explosion Proof Model |
Ex-proof crankcase oil sump heating |
N/A Optional with Explosion Proof Model only, Not available in Non-Explosion Proof Model |
Flexible drive coupling |
N/A Standard |
Direct drive Electric Motor |
N/A StandardStandard with Non-Explosion Proof model only, Not available with Explosion Proof Model |
Direct-drive Ex-motor (ATEX) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Resilient AV mounts |
N/A Standard |
Outlet flexible hose with non-return valve |
N/A Standard |
Flexible oil/water drain hose |
N/A Standard |
Auto Start-Stop pressure sensor control |
N/A Optional |
Oil/water drain gas seprator ‘Demister’ vessel |
N/A Optional |
Oil/water collection tank |
N/A Optional |
Oil/water collection tank (level alarm) |
N/A Optional |
Electrical Control Panel (Safe Area, Start/Stop, alarms, shutdowns) |
N/A Optional |
Acoustic enclosure - internal heater, fan ventilation, gas detection |
N/A Optional |
Ex-proof drive coupling (ATEX 95) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Anti-static air-blast cooling fan (ATEX 95) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Intrinsic safe relays for pressure and temperature monitoring |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Intrinsic safe terminal box for electrical connections |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Electrical Control panel to ATEX zone 1 and 2 |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Supply gas pressure sensor control (Auto-Stop/Restart) |
N/A Optional |
Supply gas isolating valve (manual, solenoid, actuator, electrical inter-lock) |
N/A Optional |
Supply gas non-return valve |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Supply gas excess flow valve |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
In-line gas suction filter |
N/A Optional |
Suction gas regulation (pressure reducing valve) |
N/A Optional |
Suction gas shut-off valve (solenoid, actuated) |
N/A Optional |
Capacity control (re-cycling by-pass valve, discharge back to suction) |
N/A Optional |
Inlet gas pulsation damper (suction 'buffer tank' inc. drain/purge valve) |
N/A Standard |
Suction gas protection (safety valve, pressure gauge, high/low pressure sensor-switch) |
N/A Standard |
Flexible suction gas hose |
N/A Optional |
Outlet oil coalescing filtration (manual, auto drain) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Outlet oil vapour activated carbon filtration (manual drain) |
N/A Optional |
Outlet purge connection |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Final Pressure Maintaining Valve |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Gas drying (suction, outlet HP Dryer) |
N/A Optional |
Auto Stop/Start pressure sensor control |
N/A Optional |
Gas recovery, or ‘blow-down’ , vessel (purge, drain, safety valve, pressure gauge) |
N/A Standard |