Mistral (‘LB’) Series inert gas boosters are dedicated nitrogen gas boosters that can accept suction pressures from 58 – 116 PSI to deliver gas to a maximum of 580 PSI. This single stage gas booster
Unit of Measure

Specifications

Stages/Cylinders

N/A 1 Stage

Models

N/A WP15L, WP22L, WP33L, WP45L, WP65L, WP33LB, WP65LB

Operating Pressure Range

N/A 150 to 580 psi

Required Power

N/A 5 to 30 hp

Flow Rate

N/A 6.9 to 140 SCFM

Features

Multi-stage oil-lubricated piston compressor

N/A Standard

Inter-stage and final after-cooler with oil/water separators

N/A Standard

Over-pressure saftey valves at each stage

N/A Standard

Gas-tight over-pressure safety valves at each stage (piped exit, manifold)

N/A Optional

Automatic oil/water drain valves

N/A Standard

Auto-starting relief integrated with drain system

N/A Standard

Pressure indicator at each stage

N/A Optional

Gas over-temperature protective shutdown sensor

N/A Standard

Oil lubrication including protection sensor

N/A Optional

Pressure and temperature indicators and sensor-switch at all stages

N/A Standard

Air-blast cooling fan and flywheel

N/A Standard

Lubricating oil level alarm

N/A Standard

Gas suction connection (flange, pipe)

N/A Standard

Crankcase oil sump heating

N/A Optional

Flexible drive coupling

N/A Standard

Direct drive Electric Motor

N/A Standard

Direct-drive Ex-motor (ATEX)

N/A Optional

Resilient AV mounts

N/A Standard

Outlet flexible hose with non-return valve

N/A Standard

Flexible oil/water drain hose

N/A Standard

Auto Start-Stop pressure sensor control

N/A Standard

Oil/water drain gas seprator ‘Demister’ vessel

N/A Optional

Oil/water collection tank

N/A Optional

Oil/water collection tank (level alarm)

N/A Optional

Electrical Control Panel (Safe Area, Start/Stop, alarms, shutdowns)

N/A Optional

Acoustic enclosure - internal heater, fan ventilation, gas detection

N/A Optional

Ex-proof drive coupling (ATEX 95)

N/A Optional

Anti-static air-blast cooling fan (ATEX 95)

N/A Optional

Electrical Control panel to ATEX zone 1 and 2

N/A Optional

Supply gas pressure sensor control (Auto-Stop/Restart)

N/A Optional

Supply gas isolating valve (manual, solenoid, actuator, electrical inter-lock)

N/A Optional

In-line gas suction filter

N/A Optional

Suction gas regulation (pressure reducing valve)

N/A Optional

Suction gas shut-off valve (solenoid, actuated)

N/A Optional

Capacity control (re-cycling by-pass valve, discharge back to suction)

N/A Optional

Inlet gas pulsation damper (suction 'buffer tank' inc. drain/purge valve)

N/A Optional

Suction gas protection (safety valve, pressure gauge, high/low pressure sensor-switch)

N/A Optional

Flexible suction gas hose

N/A Optional

Outlet oil coalescing filtration (manual, auto drain)

N/A Optional

Outlet oil vapour activated carbon filtration (manual drain)

N/A Optional

Outlet purge connection

N/A Optional

Final Pressure Maintaining Valve

N/A Optional

Gas drying (suction, outlet HP Dryer)

N/A Optional

Auto Stop/Start pressure sensor control

N/A Optional